hall sensor calibration.
Forums:
Hi,
I'm re-initializing the hall sensor table for a motor. I got 99-161-126-26-59-199. Now these are supposed to be evenly distributed on 0-200. Would it make sense to improve the running of the motor a little by by taking a 0-33-67-100-133-167 and rotating it (adding a 0-32 constant to all of them) until it matches the measured numbers as closely as possible? I have done that and set the hall table to 28-62-95-128-162-195 now (in the correct order).
- Read more about hall sensor calibration.
- 5 comments