You are here

Help i can not setup my motors

1 post / 0 new
jakson01
Offline
Last seen: 7 months 3 weeks ago
VESC Free
Joined: 2022-09-09 18:34
Posts: 1
Help i can not setup my motors

i can not setup my motors i wizard them and i typ in the terminal faults this is what he saying 

 

The following faults were registered since start:

Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 2.2
Current filtered : 1.3
Voltage          : 83.28
Duty             : 0.004
RPM              : 302.9
Tacho            : 3
Cycles running   : 124
TIM duty         : 68
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 142.05
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 9.3
Current filtered : 3.9
Voltage          : 83.12
Duty             : 0.004
RPM              : 272.7
Tacho            : 9
Cycles running   : 104
TIM duty         : 74
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 142.05
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 3.0
Current filtered : 1.5
Voltage          : 83.23
Duty             : 0.004
RPM              : 276.6
Tacho            : 15
Cycles running   : 104
TIM duty         : 73
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 153.68
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 1.6
Current filtered : 1.2
Voltage          : 83.25
Duty             : 0.005
RPM              : 269.7
Tacho            : 21
Cycles running   : 99
TIM duty         : 83
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 152.41
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 1.3
Current filtered : 1.6
Voltage          : 83.20
Duty             : 0.005
RPM              : 277.3
Tacho            : 27
Cycles running   : 99
TIM duty         : 90
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 158.65
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 3.5
Current filtered : 2.1
Voltage          : 83.25
Duty             : 0.006
RPM              : 261.9
Tacho            : 33
Cycles running   : 104
TIM duty         : 99
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 149.59
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 3.8
Current filtered : 2.6
Voltage          : 83.23
Duty             : 0.007
RPM              : 263.7
Tacho            : 39
Cycles running   : 114
TIM duty         : 120
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 134.78
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 4.9
Current filtered : 4.5
Voltage          : 83.17
Duty             : 0.009
RPM              : 254.2
Tacho            : 45
Cycles running   : 114
TIM duty         : 142
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 135.06
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 7.8
Current filtered : 7.4
Voltage          : 83.23
Duty             : 0.010
RPM              : 266.0
Tacho            : 51
Cycles running   : 109
TIM duty         : 176
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 133.68
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 12.9
Current filtered : 11.8
Voltage          : 83.23
Duty             : 0.013
RPM              : 277.9
Tacho            : 57
Cycles running   : 99
TIM duty         : 222
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 150.78
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 19.3
Current filtered : 18.7
Voltage          : 83.28
Duty             : 0.016
RPM              : 267.4
Tacho            : 63
Cycles running   : 104
TIM duty         : 269
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 16800
Comm step        : 0
Temperature      : 150.38
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : -1.8
Current filtered : -0.8
Voltage          : 83.14
Duty             : -0.002
RPM              : -302.5
Tacho            : 63
Cycles running   : 197
TIM duty         : -14
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 8400
Comm step        : 0
Temperature      : 160.11
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 13.0
Current filtered : 12.0
Voltage          : 83.14
Duty             : 0.029
RPM              : 931.8
Tacho            : 93
Cycles running   : 17627
TIM duty         : 242
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 8400
Comm step        : 0
Temperature      : 107.67
 
Fault            : FAULT_CODE_OVER_TEMP_FET
Motor            : 1
Current          : 12.1
Current filtered : 12.3
Voltage          : 83.12
Duty             : 0.024
RPM              : 5618.9
Tacho            : 977
Cycles running   : 26037
TIM duty         : 200
TIM val samp     : 2100
TIM current samp : 2100
TIM top          : 8400
Comm step        : 0
Temperature      : 110.83