Hey
Using some 75300 since beginning of the year, i´m not able to update them to newer FW then the actually ones :
HW 75-300-R3 : FW 4.2
HW 75-300-R2 : FW 3.62
Using actually VESC TOOL 2.06
Having hard times setting up bigger motors,
Inrunner 5000gramm low KV (under 50) and 4000gramm Outrunners with 50kv
The R2 only works in sensored BLDC with the Inrunners (QS Motors 1000W)
With the Outrunner (APS120) the R2 just run in FOC, but having Overcurrent Faults
R3 works only in FOC with the Inrunner, Overcurrent Faults
I read that Ben says that the older FW have Problems on 75300 and he has alot fried ones already, dont wanna be next (-;
What can i do ?
Kind Regards
Jens
adding big capacitors like 10000uF/100V on battery connections could help. Big TVS as 5KP62 or 68 also could prevent burns, calculate according to the motive voltage. you could try fw 5.2.
Thanks for the information. It really helped me!